Girder-Slab® System Specification Guide
- The open web Dissymmetric Beam shall be fabricated from (ASTM A992/A572 Grade 50) standard steel wide flange sections with flat bar at top-flange and shall meet AISC standards (except for depth, tolerance ± 1/8"), unpainted unless specified. The open web Dissymmetric Beam can be specified to include camber. Cambering can be built in during assembly of the girder.
- If the structural engineer of record determines that shoring of the pre-composite assembly is needed, leave in place until grout attains required strength.
- Precast prestressed concrete hollow core slab units (min. 5000 PSI) shall be in 4 or 8 foot widths and shall meet PCI standards and tolerances, 2" min. bearing unless specified otherwise. Open the top of each slab core for proper grout placement and inspection.
- Reinforcing steel (ASTM A615 Grade 60) shall be placed through the Dissymmetric Beam web openings and into slab cores.
- Cementitious grout (min. 4,000 PSI) shall be placed monolithically around and through the Dissymmetric Beam web openings and into slab cores filled solid for a minimum of 8", level to the slab surface with 9/16" min. average thickness over the top-flange (exceptions may apply if using concrete topping). When concrete topping is used, attain specified strength of grout prior to placement.
- The Girder-Slab System shall be constructed in accordance with Underwriters Laboratories Inc., Floor-Ceiling Assembly Design No. K912 in order to meet fire classification standards and ratings set forth by BOCA and ICC codes.
- The Girder-Slab System and D-Beam Girders shall be distributed and assembled by steel contractors authorized by Girder-Slab Technologies LLC of NJ in conformance with its Design-Guide & Distribution requirements. Steel Contractor/ Distributor contact information: 1-888-478-1100 or www.girder-slab.com.
- The Distributor of the Girder-Slab System shall provide to the Project Owner (or its representative) a Girder-Slab Compliance Certificate for each project upon completion of system assembly and construction.
- Comply with all applicable provisions of the following standards and codes:
- Girder-Slab Technologies LLC Design-Guide
- American Institute of Steel Construction (AISC)
- American Welding Society (AWS)
- Precast Concrete Institute (PCI)
- American Concrete Institute (ACI)
- American Society of Testing and Materials (ASTM)
- Underwriters Laboratories Inc. (UL) - Fire Resistance Directory
- Building Officials and Code Administrators International Inc. (BOCA) - National Building Code
- International Code Council Inc. (ICC) - International Building Code
- Other applicable codes and standards